High-frequency, Low Tidal Volume Ventilation: Improving Catheter Stability During Atrial Fibrillation Ablation

DOI: 10.19102/icrm.2014.050806

1CHAD A. STOCKINGER, RT(R), 1JESSICA COOKE, RN, 2MICHAEL NUNEZ, MD and 1,2CHRISTOPHER COLE, MD, FACC, FHRS

1The Vascular Center of Colorado, Colorado Springs, CO

2Penrose-St. Francis Healthcare, Colorado Springs, CO

PDF Download PDF
tweeter Follow Us >>

KEYWORDS.anesthesia, isolation, stability, tidal, ventilation.

The authors report no conflicts of interest for the published content.
Manuscript received April 29, 2014, final version accepted May 6, 2014.

Address correspondence to: Chad Stockinger, AAS, The Vascular Center of Colorado, Electrophysiology Lab, 2222 North Nevada Ave, Suite 3000, Colorado Springs, CO 80907.
E-mail: cstockinger@vasc-center.com

Introduction

Catheter stability is integral to a successful atrial fibrillation ablation and jet ventilation has been used to minimize catheter motion. We describe a novel technique; high frequency, low tidal volume (HFLTV) ventilation, to accomplish the same goal using only a conventional anesthesia machine and ventilator.

crm-05-08-1726-f1.jpg

Figure 1: HFLTV ventilation vs. standard ventilation respiratory motion comparative view via Biosense Webster CARTO® 3 ACCURESP module

Results

A 57-year-old male with long-standing, persistent atrial fibrillation underwent a radiofrequency ablation under general anesthesia using a Datex-Ohmeda Aespire View (GE Healthcare, Madison, WI) anesthesia machine. The total procedure time was 93 min, including 8.6 min of fluoroscopy and 58.1 min of radiofrequency (RF) ablation time. Using 35–40 mmHg end tidal CO2 (ETCO2) as a baseline, our team alternated between hyperventilating the patient to 30 mmHg ETCO2 for approximately 5 minutes, and then, for the subsequent 15 min we utilized 100 mL tidal volumes at a rate of 80 breaths per minute. While ETCO2 levels trended upwards during HFLTV ventilation, this effect was mitigated by the intermittent hyperventilation. Respiratory motion was substantially reduced, resulting in increased catheter contact.

Conclusions

Catheter stability improves RF energy delivery and creates better ablation lesions. Our case study reports a previously undescribed technique that substantially improves stability and can be easily implemented in the electrophysiology laboratory with a conventional anesthesia ventilator.